Fulltext TSBs

Technical Service Bulletins

TSB
97-19-19
  • AIR CONDITIONING – NO AIRFLOW FROM FLOOR
  • HEATER – NO AIRFLOW FROM FLOOR
Publication Date: SEPTEMBER 15, 1997

LIGHT TRUCK:
1997 EXPEDITION, F-150-350 SERIES

ISSUE:

Airflow from the air conditioner or heater will not switch to FLOOR mode on some vehicles. This may be due to the panel/floor door vacuum motor linkage being disconnected from the door pivot.

ACTION:

Replace the vacuum motor assembly. Refer to the following Service Procedure for details.

SERVICE PROCEDURE

  1. Verify concern.
  2. Remove and replace panel/floor door Vacuum Motor (F75Z-18A318-AA). Refer to the appropriate Service Manual for removal procedure. Make sure linkage is fully engaged in door pivot.
  3. Verify proper heating system operation.

PART NUMBERPART NAME
F75Z-18A318-AAVacuum Motor Assembly

OTHER APPLICABLE ARTICLES:

NONE

WARRANTY STATUS:

Eligible Under The Provisions Of Bumper To Bumper Warranty Coverage

OPERATIONDESCRIPTIONTIME
971919AReplace Vacuum Motor Assembly0.6 Hr.

DEALER CODING

BASIC PART NO.CONDITION CODE
18A318X2

OASIS CODES:

208000, 208300, 208999


Copyright 1997 Ford Motor Company